NSSP-PR Design of Sprinklers Systems
- Description
- Curriculum
- Reviews
1. Course Overview
This course develops professional-level competency in designing sprinkler and fire-pump systems in accordance with NFPA 13 and NFPA 20. Participants complete multiple design projects including hazard classification, hydraulic calculations, sprinkler layout design, and fire pump sizing using pump curves.
2. Course Objectives & Learning Outcomes
2.1 Course Objectives
-
Apply NFPA 13 and NFPA 20 requirements correctly in design practice.
-
Perform hydraulic calculations for sprinkler systems.
-
Select and size fire pumps based on demand curves and system design.
-
Develop compliant engineering design drawings and submittals.
-
Apply professional quality assurance and documentation control.
2.2 Learning Outcomes
Upon successful completion, participants will be able to:
-
Classify hazards in accordance with NFPA 13.
-
Design sprinkler system layouts including spacing, coverage, and piping configuration.
-
Develop complete hydraulic calculation packages.
-
Select and size fire pumps in accordance with NFPA 20.
-
Prepare complete NFPA-aligned submission packages.
3. Target Audience
This course is designed for:
-
Fire protection engineers
-
Designers
-
Consultants
-
AHJ reviewers
-
Senior technicians transitioning to design
4. Course Modules & Time Allocation
|
Module |
Topic |
Training Type |
Duration |
|
1 |
NFPA Design Framework & Hazard Classification |
Theoretical |
10 hours |
|
2 |
Sprinkler System Layout & Hydraulic Design |
Theoretical / Practical |
10 hours |
|
3 |
Storage, Special Sprinklers & Advanced Hydraulic Considerations |
Theoretical / Practical |
16 hours |
|
4 |
Fire Pump & Water Supply Design |
Theoretical / Practical |
10 hours |
|
5 |
Integrated Design Project, QA & Submittals |
Workshop Case Studies + Final Exam |
10 hours |
5. Assessment & Passing Requirements
Passing mark for this course is 70%.
|
Assessment Item |
Method |
Weight |
Pass Requirement |
|
Written Final Exam |
Multiple Choice (35 questions) |
40% |
≥ 70% |
|
Design Project |
Complete System Design |
40% |
≥ 70% |
|
Final Case Study |
Engineering Justification Report |
20% |
≥ 70% |
|
Attendance |
|
Mandatory |
≥ 90% |
To be certified, the student must pass theory and design independently.
6. Certificate
Participants who meet attendance requirements and achieve a final score of at least 70% will receive a certificate of successful completion for “NSSP–PR Design of Sprinkler Systems & Fire Pumps – Professional Level” issued by NAF Fire Training School.
7. Training Safety & Trainee Protection Measures
All design activities are classroom based. However, any site visits or lab demonstrations will follow NAF Fire Training School HSE procedures. Participants must comply with trainer instructions at all times.
8. Daily Training Schedule
|
Day & Time |
Module |
Session Title |
Training Delivery |
|
Day 1 (09:00–17:00) |
Module 1 |
Design Foundations & NFPA Framework |
Theoretical + Demonstration |
|
Day 2 (09:00–17:00) |
Module 2 |
Hazard Classification & Design Criteria |
Theoretical + Demonstration |
|
Day 3 (09:00–17:00) |
Module 3 |
Hydraulic Calculations (Sprinklers)
|
Theoretical + Workshop |
|
Day 4 (09:00–17:00) |
Module 3 Module 4 |
Advanced Systems & Special Hazards Fire Pumps & System Demand |
Theoretical + Workshop |
|
Day 5 (09:00–17:00) |
Module 5 |
Integrated Design & Coordination |
Theoretical + Workshop |
|
Day 6 (09:00–17:00) |
Design Workshop |
Full Project Design |
Theoretical + Workshop |
|
Day 7 (09:00–17:00) |
Final Assessment |
Final Assessment & Design Defense |
Practical + Theoretical Assessment |
9. Course Disclaimer
This course is independently developed and delivered by NAF Fire Training School.
The course content is designed in alignment with internationally recognized standards and best practices in fire protection, life safety, and emergency systems, including relevant standards issued by the National Fire Protection Association (NFPA) and other applicable international references, where appropriate.
NAF Fire Training School is not affiliated with, endorsed by, certified by, or approved by the National Fire Protection Association (NFPA) or any other standards-issuing body, unless explicitly stated otherwise.
Any reference to NFPA standards is for educational and informational purposes only. NFPA® is a registered trademark of the National Fire Protection Association.
10. Document Control & Versioning
This is a controlled document. Uncontrolled copies are not updated.
Document Title: NSSP‑PR Course Syllabus (English Version)
Document Code: NAF-TR-NSSP-PR-01
Version: 1.0
Status: Approved Document
-
1NFPA Design Framework & Hazard Classification
Theoretical
-
2Sprinkler System Layout & Hydraulic Design
Theoretical / Practical
-
3Storage, Special Sprinklers & Advanced Hydraulic Considerations
Theoretical / Practical
-
4Fire Pump & Water Supply Design
Theoretical / Practical
-
5Integrated Design Project, QA & Submittals
Workshop Case Studies + Final Exam