This course develops professional-level competency in designing sprinkler and fire-pump systems in accordance with NFPA 13 and NFPA 20.
Instructor
dev
0
0 reviews
  • Description
  • Curriculum
  • Reviews
course2

1. Course Overview

This course develops professional-level competency in designing sprinkler and fire-pump systems in accordance with NFPA 13 and NFPA 20. Participants complete multiple design projects including hazard classification, hydraulic calculations, sprinkler layout design, and fire pump sizing using pump curves. 

 

2. Course Objectives & Learning Outcomes

2.1 Course Objectives 

  • Apply NFPA 13 and NFPA 20 requirements correctly in design practice. 

  • Perform hydraulic calculations for sprinkler systems. 

  • Select and size fire pumps based on demand curves and system design. 

  • Develop compliant engineering design drawings and submittals. 

  • Apply professional quality assurance and documentation control. 

 

2.2 Learning Outcomes 

Upon successful completion, participants will be able to: 

  • Classify hazards in accordance with NFPA 13. 

  • Design sprinkler system layouts including spacing, coverage, and piping configuration. 

  • Develop complete hydraulic calculation packages. 

  • Select and size fire pumps in accordance with NFPA 20. 

  • Prepare complete NFPA-aligned submission packages. 

 

 

3. Target Audience 

This course is designed for: 

  • Fire protection engineers 

  • Designers 

  • Consultants 

  • AHJ reviewers 

  • Senior technicians transitioning to design 

 

4. Course Modules & Time Allocation 

Module 

Topic 

Training Type 

Duration 

1 

NFPA Design Framework & Hazard Classification 

Theoretical 

10 hours 

2 

Sprinkler System Layout & Hydraulic Design  

Theoretical / Practical 

10 hours 

3 

Storage, Special Sprinklers & Advanced Hydraulic Considerations 

Theoretical / Practical 

16 hours 

4 

Fire Pump & Water Supply Design  

Theoretical / Practical 

10 hours 

5 

Integrated Design Project, QA & Submittals 

Workshop Case Studies + Final Exam 

10 hours 

 

 

5. Assessment & Passing Requirements 

Passing mark for this course is 70%.

Assessment Item 

Method 

Weight 

Pass Requirement 

Written Final Exam 

Multiple Choice (35 questions) 

40% 

≥ 70% 

Design Project 

Complete System Design 

40% 

≥ 70% 

Final Case Study  

Engineering Justification Report 

20% 

≥ 70% 

Attendance 

 

Mandatory 

≥ 90% 


To be certified, the student must
pass theory and design independently. 

 

6. Certificate 

Participants who meet attendance requirements and achieve a final score of at least 70% will receive a certificate of successful completion for NSSP–PR Design of Sprinkler Systems & Fire Pumps – Professional Level issued by NAF Fire Training School. 

 

7. Training Safety & Trainee Protection Measures 

All design activities are classroom based. However, any site visits or lab demonstrations will follow NAF Fire Training School HSE procedures. Participants must comply with trainer instructions at all times. 

 

8. Daily Training Schedule

Day & Time 

Module 

Session Title 

Training Delivery 

Day 1 (09:00–17:00) 

Module 1  

Design Foundations & NFPA Framework 

Theoretical + Demonstration 

Day 2 (09:00–17:00) 

Module 2 

Hazard Classification & Design Criteria 

Theoretical + Demonstration 

Day 3 (09:00–17:00) 

Module 3 

Hydraulic Calculations (Sprinklers)  

 

Theoretical + Workshop 

Day 4 (09:00–17:00) 

Module 3 

Module 4 

Advanced Systems & Special Hazards 

Fire Pumps & System Demand 

Theoretical + Workshop 

Day 5 (09:00–17:00) 

Module 5 

Integrated Design & Coordination 

Theoretical + Workshop 

Day 6 (09:00–17:00) 

Design Workshop 

Full Project Design 

Theoretical + Workshop 

Day 7 (09:00–17:00) 

Final Assessment 

Final Assessment & Design Defense 

Practical + Theoretical Assessment 

 

9. Course Disclaimer  

This course is independently developed and delivered by NAF Fire Training School. 

The course content is designed in alignment with internationally recognized standards and best practices in fire protection, life safety, and emergency systems, including relevant standards issued by the National Fire Protection Association (NFPA) and other applicable international references, where appropriate. 

NAF Fire Training School is not affiliated with, endorsed by, certified by, or approved by the National Fire Protection Association (NFPA) or any other standards-issuing body, unless explicitly stated otherwise. 

Any reference to NFPA standards is for educational and informational purposes only. NFPA® is a registered trademark of the National Fire Protection Association. 

 

10. Document Control & Versioning 

This is a controlled document. Uncontrolled copies are not updated. 

Document Title:  NSSPPR Course Syllabus (English Version)

Document Code: NAF-TR-NSSP-PR-01

Version: 1.0

Status: Approved Document 

 

Certificate included
Course details
Duration 7 Days (56 Hours)
Lectures 5
Quizzes 4
Level Professional
Basic info

Course Code: NSSP-PR 

Training Language: English

Pass Mark: 70%

Course requirements

Recommended Prerequisites: 

  • Completion of NSWB-P (Water-Based Fire Protection Systems – Practitioner) or equivalent field/engineering experience. 

  • Comfort with: 

  • Basic algebra, unit conversions 

  • Pressure & flow concepts 

  • Reading simple piping schematics